Inertsil ODS 3V
- Supporting validation of creating or using analytical method.
- GL Sciences columns are manufactured through development, manufacturing and inspection, under strict quality control to gain good lot-to-lot reproducibility.
- Inertsil ODS-3V columns are also available in 3-column-sets packed with your choice of 3 different silica batches or a single silica batch to assist in reproducibility studies.
Specifically Qualified HPLC Columns for GLP/GMP Compliance Validation.
Inertsil ODS-3V offers all of the outstanding chromatographic benefits of Inertsil ODS-3 with the added benefit of a more thoroughly documented, validated QC procedure consistent with the demands of GLP/GMP compliance. Each Inertsil ODS-3V is delivered with a Manufacturer’s Validation Certificate showing the detailed results of every QA and QC step in manufacturing. The use of Inertsil ODS-3V columns provides an extra measure of assurance of consistent performance from column to column and batch to batch. Inertsil ODS-3V columns are also available in 3-column-sets packed with your choice of 3 different silica batches or a single silica batch to assist in reproducibility studies.
Functional Group:
Base Material: | 3 Series High Purity Silica |
Particle Size: | 5 µm |
Surface Area: | 450 m²/g |
Pore Size: | 100 Å (10 nm) |
Pore Volume: | 1.05 mL/g |
Functional Group: | Octadecyl |
End-capping: | Yes |
Carbon Loading: | 15.0 % |
USP Code: | L1 |
pH Range: | 2 - 7.5 |
I.D.: | 3.0, 4.0, 4.6 mm |
All Products for Inertsil ODS 3V
Particle Size
Length
150mm | 250mm | 50mm |
75mm | 100mm |
Column ID
4.600 | 4.000 | 3.000 |
2.100 |
Part Number | Part Name | Particle Size | Length | Column ID | Qty |
---|---|---|---|---|---|
5020-01801 | Inertsil ODS-3V (Validated) 5um Column 4.6 x 150mm | 150mm | 4.600 | ||
5020-01802 | Inertsil ODS-3V (Validated) 5um Column 4.6 x 250mm | 250mm | 4.600 | ||
5020-01811 | Inertsil ODS-3V (Validated) 5um Column 4.0 x 150mm | 150mm | 4.000 | ||
5020-01812 | Inertsil ODS-3V (Validated) 5um Column 4.0 x 250mm | 250mm | 4.000 | ||
5020-01821 | Inertsil ODS-3V (Validated) 5um Column 3.0 x 150mm | 150mm | 3.000 | ||
5020-01822 | Inertsil ODS-3V (Validated) 5um Column 3.0 x 250mm | 250mm | 3.000 | ||
5020-30112 | Inertsil ODS-3V (Validated) 3um Column 2.1 x 50mm | 50mm | 2.100 | ||
5020-30113 | Inertsil ODS-3V (Validated) 3um Column 2.1 x 75mm | 75mm | 2.100 | ||
5020-30114 | Inertsil ODS-3V (Validated) 3um Column 2.1 x 100mm | 100mm | 2.100 | ||
5020-30115 | Inertsil ODS-3V (Validated) 3um Column 2.1 x 150mm | 150mm | 2.100 | ||
5020-30116 | Inertsil ODS-3V (Validated) 3um Column 2.1 x 250mm | 250mm | 2.100 | ||
5020-30122 | Inertsil ODS-3V (Validated) 3um Column 3.0 x 50mm | 50mm | 3.000 | ||
5020-30123 | Inertsil ODS-3V (Validated) 3um Column 3.0 x 75mm | 75mm | 3.000 | ||
5020-30124 | Inertsil ODS-3V (Validated) 3um Column 3.0 x 100mm | 100mm | 3.000 | ||
5020-30125 | Inertsil ODS-3V (Validated) 3um Column 3.0 x 150mm | 150mm | 3.000 | ||
5020-30126 | Inertsil ODS-3V (Validated) 3um Column 3.0 x 250mm | 250mm | 3.000 | ||
5020-30132 | Inertsil ODS-3V (Validated) 3um Column 4.0 x 50mm | 50mm | 4.000 | ||
5020-30133 | Inertsil ODS-3V (Validated) 3um Column 4.0 x 75mm | 75mm | 4.000 | ||
5020-30134 | Inertsil ODS-3V (Validated) 3um Column 4.0 x 100mm | 100mm | 4.000 | ||
5020-30135 | Inertsil ODS-3V (Validated) 3um Column 4.0 x 150mm | 150mm | 4.000 | ||
5020-30136 | Inertsil ODS-3V (Validated) 3um Column 4.0 x 250mm | 250mm | 4.000 | ||
5020-30142 | Inertsil ODS-3V (Validated) 3um Column 4.6 x 50mm | 50mm | 4.600 | ||
5020-30143 | Inertsil ODS-3V (Validated) 3um Column 4.6 x 75mm | 75mm | 4.600 | ||
5020-30144 | Inertsil ODS-3V (Validated) 3um Column 4.6 x 100mm | 100mm | 4.600 | ||
5020-30145 | Inertsil ODS-3V (Validated) 3um Column 4.6 x 150mm | 150mm | 4.600 | ||
5020-30146 | Inertsil ODS-3V (Validated) 3um Column 4.6 x 250mm | 250mm | 4.600 |